2MHz standard      
     

The 2MHz dual crystal transducer with a diameter of 12mm / 0.47" is used to measure materials with high attenuation levels.

Measuring Range: 4 to 500mm / 0.15" to 19.68"
Cable Length: 1m / 3.28ft
Connectors: 02 each type Lemo 00 male connectors
Working Temp: -10 to 40ºC / 14 to 104ºF

 
  2MHz standard      
   

The 2MHz dual crystal transducer with a diameter of 22mm / 0.86" is primarily used to measure thickness in founded or forged parts.

Measuring Range: 8 to 500mm / 0.31" to 19.68"
Probe Connectors: 02 each type Lemo 00 female connectors
Cable: 1m / 3.28ft long with type Lemo 00 male connectors (02 each end)
Working Temp: -10 to 40ºC / 14 to 104ºF

 
  5MHz standard      
   

The 5MHz dual crystal transducer with a diameter of 10mm / 0.39" is the standard transducer already included with all dmq pulse-echo wall thickness gauges.

Measuring Range: 1 to 250mm / 0.039" to 9.84"
Cable Length: 1m / 3.28ft
Connectors: 02 each type Lemo 00 male connectors
Working Temp: -10 to 40ºC / 14 to 104ºF

 
  7MHz standard      
    The 7MHz transducer has a diameter of 6 mm / 0.23" and is primarily used to measure curved and or small parts.

Measuring Range: 0.8 to 100mm / 0.031" to 3.93"
Cable Length: 1m / 3.28ft
Connectors: 02 each type Lemo 00 male connectors
Working Temp: -10 to 40ºC / 14 to 104ºF

 
 
     
   
 

Transducers for QS5 E and QS5 DLE models only

 
  2MHz hi-damp      
  2MHz Hi-Damp   The "hi-damp" 2MHz transducer with a diameter of 12mm / 0.47" is used to measure in pulse-echo as well as echo-echo or thru-paint.

Measuring Range Echo-Echo (Thru-Paint): 4 a 35mm /  
Measuring Range Pulse-Echo: 4 to 500mm /
Cable Length: 1m / 3.28ft
Connectors: 02 each type Lemo 00 male connectors
Working Temp: -15 to 70ºC / 5 to 158ºF

 
  5MHz hi-damp      
    The "hi-damp" 5MHz transducer with a diameter of 12mm / 0.47" is used to measure in pulse-echo as well as echo-echo or thru-paint.

Measuring Range Echo-Echo (Thru-Paint): 2.5 a 25mm / 0.098 a 0.98" 
Measuring Range Pulse-Echo: 1.5 to 150mm / 0.059" to 5.90"
Cable Length: 1m / 3.28ft
Connectors: 02 each type Lemo 00 male connectors
Working Temp: -15 to 70ºC / 5 to 158ºF

 
  5MHz hi-damp      
      This "hi-damp" 5MHz transducer uses a separate cable and it is also used to measure in pulse-echo as well as echo-echo or thru-paint.

Measuring Range Echo-Echo (Thru-Paint): 2.5 a 25mm / 0.098 a 0.98" 
Measuring Range Pulse-Echo: 1.5 to 150mm / 0.059" to 5.90"
Probe Connectors: 02 each type Lemo 00 female connectors
Cable: 1m / 3.28ft long with type Lemo 00 male connectors (02 each end)
Working Temp: -15 to 70ºC / 5 to 158ºF

 
Specialty transducers can be built upon request. Contact us with details.
 
   
  Calibration Blocks      
   

 

Individual test blocks and step blocks are available (4, 5, 6, and 10 steps), millimeters and inches. Contact us

 

 
 
     
   
  Gel      
   

Standard coupling gel that can be used in most surfaces.
Presented in a 100g / 3.52oz plastic bottle.

 
         
     
   
  Silicone Protection      
   

A silicone protective cover is offered to protect the electronic unit. Recommended for instruments that will be used in the field.

 
         
     
   
  Printer      
   

Print results immediately instead of having to download data so that you can then print from a PC.

 
         
         